282 research outputs found

    MEASURING THE PROCESS EFFICIENCY OF CONTROLLED WELDING PROCESSES

    Get PDF
    This The process efficiency in Seem and Arc Welding is a crucial input to Mathematical models of the process and requires the use of an accurate welding calorimeter. In this paper we compare a liquid nitrogen calorimeter with an insulated box calorimeter for measuring the process efficiency of Fronius CMT, Lincoln STT and Rapid Arc, Kemppi FastRoot and standard pulsed GMAW. All the controlled dip transfer processes had a process efficiency of around 85% when measured with the liquid nitrogen calorimeter

    An interference-aware virtual clustering paradigm for resource management in cognitive femtocell networks

    Get PDF
    Femtocells represent a promising alternative solution for high quality wireless access in indoor scenarios where conventional cellular system coverage can be poor. They are randomly deployed by the end user, so only post deployment network planning is possible. Furthermore, this uncoordinated deployment creates severe interference to co-located femtocells, especially in dense deployments. This paper presents a new architecture using a generalised virtual cluster femtocell (GVCF) paradigm, which groups together FAP into logical clusters. It guarantees severely interfering and overlapping femtocells are assigned to different clusters. Since each cluster operates on different band of frequencies, the corresponding virtual cluster controller only has to manage its own FAPs, so the overall system complexity is low. The performance of the GVCF algorithm is analysed from both a resource availability and cluster number perspective. Simulation results conclusively corroborate the superior performance of the GVCF model in interference mitigation, particularly in high density FAP scenarios

    Bayesian Inference in Processing Experimental Data: Principles and Basic Applications

    Full text link
    This report introduces general ideas and some basic methods of the Bayesian probability theory applied to physics measurements. Our aim is to make the reader familiar, through examples rather than rigorous formalism, with concepts such as: model comparison (including the automatic Ockham's Razor filter provided by the Bayesian approach); parametric inference; quantification of the uncertainty about the value of physical quantities, also taking into account systematic effects; role of marginalization; posterior characterization; predictive distributions; hierarchical modelling and hyperparameters; Gaussian approximation of the posterior and recovery of conventional methods, especially maximum likelihood and chi-square fits under well defined conditions; conjugate priors, transformation invariance and maximum entropy motivated priors; Monte Carlo estimates of expectation, including a short introduction to Markov Chain Monte Carlo methods.Comment: 40 pages, 2 figures, invited paper for Reports on Progress in Physic

    Active vitamin D (1,25-dihydroxyvitamin D) and bone health in middle-aged and elderly men: the European male aging study (EMAS)

    Get PDF
    <p>Context: There is little information on the potential impact of serum 1,25-dihydroxyvitamin D [1,25(OH)2D] on bone health including turnover.</p> <p>Objective: The objective of the study was to determine the influence of 1,25(OH)2D and 25-hydroxyvitamin D [25(OH)D] on bone health in middle-aged and older European men.</p> <p>Design, Setting, and Participants: Men aged 40–79 years were recruited from population registers in 8 European centers. Subjects completed questionnaires that included questions concerning lifestyle and were invited to attend for quantitative ultrasound (QUS) of the heel, assessment of height and weight, and a fasting blood sample from which 1,25(OH)2D, 25(OH)D, and PTH were measured. 1,25(OH)2D was measured using liquid chromatography tandem mass spectrometry. Bone markers serum N-terminal propeptide of type 1 procollagen (P1NP) and crosslinks (β-cTX) were also measured. Dual-energy x-ray absorptiometry (DXA) of the hip and lumbar spine was performed in 2 centers.</p> <p>Main Outcome Measure(s): QUS of the heel, bone markers P1NP and β-cTX, and DXA of the hip and lumbar spine were measured.</p> <p>Results: A total of 2783 men, mean age 60.0 years (SD 11.0) were included in the analysis. After adjustment for age and center, 1,25(OH)2D was positively associated with 25(OH)D but not with PTH. 25(OH)D was negatively associated with PTH. After adjustment for age, center, height, weight, lifestyle factors, and season, 1,25(OH)2D was associated negatively with QUS and DXA parameters and associated positively with β-cTX. 1,25(OH)2D was not correlated with P1NP. 25(OH)D was positively associated with the QUS and DXA parameters but not related to either bone turnover marker. Subjects with both high 1,25(OH)2D (upper tertile) and low 25(OH)D (lower tertile) had the lowest QUS and DXA parameters and the highest β-cTX levels.</p> <p>Conclusions: Serum 1,25(OH)2D is associated with higher bone turnover and poorer bone health despite being positively related to 25(OH)D. A combination of high 1,25(OH)2D and low 25(OH)D is associated with the poorest bone health.</p&gt

    Active vitamin D (1,25-dihydroxyvitamin D) and bone health in middle-aged and elderly men: the European male aging study (EMAS)

    Get PDF
    <p>Context: There is little information on the potential impact of serum 1,25-dihydroxyvitamin D [1,25(OH)2D] on bone health including turnover.</p> <p>Objective: The objective of the study was to determine the influence of 1,25(OH)2D and 25-hydroxyvitamin D [25(OH)D] on bone health in middle-aged and older European men.</p> <p>Design, Setting, and Participants: Men aged 40–79 years were recruited from population registers in 8 European centers. Subjects completed questionnaires that included questions concerning lifestyle and were invited to attend for quantitative ultrasound (QUS) of the heel, assessment of height and weight, and a fasting blood sample from which 1,25(OH)2D, 25(OH)D, and PTH were measured. 1,25(OH)2D was measured using liquid chromatography tandem mass spectrometry. Bone markers serum N-terminal propeptide of type 1 procollagen (P1NP) and crosslinks (β-cTX) were also measured. Dual-energy x-ray absorptiometry (DXA) of the hip and lumbar spine was performed in 2 centers.</p> <p>Main Outcome Measure(s): QUS of the heel, bone markers P1NP and β-cTX, and DXA of the hip and lumbar spine were measured.</p> <p>Results: A total of 2783 men, mean age 60.0 years (SD 11.0) were included in the analysis. After adjustment for age and center, 1,25(OH)2D was positively associated with 25(OH)D but not with PTH. 25(OH)D was negatively associated with PTH. After adjustment for age, center, height, weight, lifestyle factors, and season, 1,25(OH)2D was associated negatively with QUS and DXA parameters and associated positively with β-cTX. 1,25(OH)2D was not correlated with P1NP. 25(OH)D was positively associated with the QUS and DXA parameters but not related to either bone turnover marker. Subjects with both high 1,25(OH)2D (upper tertile) and low 25(OH)D (lower tertile) had the lowest QUS and DXA parameters and the highest β-cTX levels.</p> <p>Conclusions: Serum 1,25(OH)2D is associated with higher bone turnover and poorer bone health despite being positively related to 25(OH)D. A combination of high 1,25(OH)2D and low 25(OH)D is associated with the poorest bone health.</p&gt

    Photodegradation of Selected PCBs in the Presence of Nano-TiO2 as Catalyst and H2O2 as an Oxidant

    Get PDF
    Photodegradation of five strategically selected PCBs was carried out in acetonitrile/water 80:20. Quantum chemical calculations reveal that PCBs without any chlorine on ortho-positions are closer to be planar, while PCBs with at least one chlorine atoms at the ortho-positions causes the two benzene rings to be nearly perpendicular. Light-induced degradation of planar PCBs is much slower than the perpendicular ones. The use of nano-TiO2 speeds up the degradation of the planar PCBs, but slows down the degradation of the non-planar ones. The use of H2O2 speeds up the degradation of planar PCBs greatly (by >20 times), but has little effect on non-planar ones except 2,3,5,6-TCB. The relative photodegradation rate is: 2,2′,4,4′-TCB > 2,3,5,6-TCB > 2,6-DCB ≈ 3,3′,4,4′-TCB > 3,4′,5-TCB. The use of H2O2 in combination with sunlight irradiation could be an efficient and “green” technology for PCB remediation
    corecore